DIAGNOSTICS - HORN                                 04-363

                                                           (d)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                                            Multimeter connection          Standard value
                                                                                                                     04
                                                              Horn switch - ground              < 2 Ω













                 Check whether the result is normal?
                 Yes > Replace the horn switch.
                 No > Maintenance or replace harness.


                 7 .    Check the harness and connectors (horn relay - horn)
                 (a)    Ignition Switch: OFF.
                 (b)    Unplug the horn relay R13.

                                                           (c)    Disconnect the connector A018 of bass horn.
                                                           (d)    Disconnect the connector A017 of althorn.