04-364                                DIAGNOSTICS - HORN

                                                      (e)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

                                                       Multimeter connection          Standard value
      04                   R13                  A018
                                                        R13(5)-A018(1)
                                                                                          < 2 Ω
                                                        R13(5)-A017(1)






                                            ftwxd041385


           Check whether the result is normal?
           Yes> go to step 8
           No > Maintenance or replace harness.


           8 .    Check the harness and connectors (horn - ground)
           (a)    Ignition Switch: OFF.

                                                      (c)    Disconnect the connector A018 of bass horn.
                                                      (d)    Disconnect the connector A017 of althorn.



















                                            ftwx811002