Page 502 - Workshop Manual - Tunland (2017)
P. 502
04-364 DIAGNOSTICS - HORN
(e) Measure the electrical resistance based on
the value in the following form.
Standard electrical resistance (check
whether there existent an open circuit)
Multimeter connection Standard value
04 R13 A018
R13(5)-A018(1)
< 2 Ω
R13(5)-A017(1)
ftwxd041385
Check whether the result is normal?
Yes> go to step 8
No > Maintenance or replace harness.
8 . Check the harness and connectors (horn - ground)
(a) Ignition Switch: OFF.
(c) Disconnect the connector A018 of bass horn.
(d) Disconnect the connector A017 of althorn.
ftwx811002