DIAGNOSTICS - HORN                                 04-365

                                                           (e)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                                            Multimeter connection          Standard value
                                A018
                                                                                                                     04
                                                               A018 (2) - ground
                                                                                                < 2 Ω
                                                               A017 (2) - ground







                                                 ftwxd041386


                 Check whether the result is normal?
                 Yes> Replace the horn.
                 No > Maintenance or replace harness.