04-380                         DIAGNOSTICS - LIGHTING SYSTEM

                                                      (b)    Disconnect the connector C008 of
                                                             combination switch (lamplight switchover).







      04





                                           ftwx641019

                                                      (c)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

                                            C008
                                                       Multimeter connection          Standard value
                                                         C008 (19) - ground               < 2 Ω










                                           ftwxd041390

           Check whether the result is normal?
           Yes> go to step 10

           No > Maintenance or replace harness.

           10 .   Check the wiring harness and connectors (BCM controlling unit - combination
                  switch)