Page 519 - Workshop Manual - Tunland (2017)
P. 519
DIAGNOSTICS - LIGHTING SYSTEM 04-381
(c) Disconnect the connector C036 of BCM
control unit.
04
ftwxd041026
(d) Measure the electrical resistance based on
the value in the following form.
Standard electrical resistance (check
whether there existent an open circuit)
Multimeter connection Standard value
C036
C036(E7)-C040 < 2 Ω
(20)
C040
ftwxd041391
Check whether the result is normal?
Yes> Replace BCM control unit.
No > Maintenance or replace harness.