Page 519 - Workshop Manual - Tunland (2017)
P. 519

DIAGNOSTICS - LIGHTING SYSTEM                            04-381

                                                           (c)    Disconnect the connector C036 of BCM
                                                                  control unit.







                                                                                                                     04





                                                 ftwxd041026

                                                           (d)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                                            Multimeter connection          Standard value

                     C036
                                                               C036(E7)-C040                    < 2 Ω
                                                                     (20)





                                       C040









                                                 ftwxd041391


                 Check whether the result is normal?
                 Yes> Replace BCM control unit.
                 No > Maintenance or replace harness.
   514   515   516   517   518   519   520   521   522   523   524