Page 524 - Workshop Manual - Tunland (2017)
P. 524

04-386                         DIAGNOSTICS - LIGHTING SYSTEM

                                                      (e)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard electrical resistance (check
                   A011
                                                             whether there existent an open circuit)
                 1  2  3                               Multimeter connection          Standard value
                 4  5  6
      04
                                                          A011 (5) - ground
                                                                                          < 2 Ω
                       A003                               A003 (5) - ground

                      1  2  3
                      4  5  6



                                           ftwxd041001


           Check whether the result is normal?
           Yes> go to step 7
           No > Maintenance or replace harness.


           7 .    Check the harness and connectors (passing lamp relay - BCM control unit)
           (a)    Ignition Switch: OFF.
           (b)    Unplug the fog lamp relay R2.

                                                      (c)    Disconnect connector C035, BCM control unit.
















                                           ftwxd041025

                                                      (d)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)
                                              C035
                                                       Multimeter connection          Standard value
                               16  15  14 13  12  11  10  9  8 7  6 5  4  3 2  1
                               32  31  30  29  28  27 26  25  24  23  22  21 20 19  18  17
                                                         R2(2)-C035(D6)                   < 2 Ω





                  2
                  4  5  3  R2
                  1
                                           ftwxd041002
   519   520   521   522   523   524   525   526   527   528   529