Page 525 - Workshop Manual - Tunland (2017)
P. 525
DIAGNOSTICS - LIGHTING SYSTEM 04-387
Check whether the result is normal?
Yes> go to step 8
No > Maintenance or replace harness.
8 . Check the combination switch (lamplight switchover)
(a) Ignition Switch: OFF. 04
(b) Disconnect the connector C008 of
combination switch (lamplight switchover).
ftwx641019
(c) Check the combination switch (lamplight
switchover)
Standard voltage
Connecting
Specified
Conditions pins of
value
multimeter
Turn off the
passing lamp 11-12 ≥ 1 MΩ
switch
Turn on the
passing lamp 11-12 < 2 Ω
switch
Check whether the result is normal?
Yes> go to step 9
No > Replace the combination switch.
9 . Check the harness and connectors (combination switch - ground)
(a) Ignition Switch: OFF.