Page 527 - Workshop Manual - Tunland (2017)
P. 527
DIAGNOSTICS - LIGHTING SYSTEM 04-389
(c) Disconnect the connector C036 of BCM
control unit.
04
ftwxd041026
(d) Measure the resistance as per the values
given in the table below
Standard electrical resistance (check
whether there existent an open circuit)
C036
Multimeter connection Standard value
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
C036(E6)-C008(12) < 2 Ω
C008
10 9 8 7 6 5 4 3 2 1
20 19 18 17 16 15 14 13 12 11
ftwxd041004
Check whether the result is normal?
Yes> Replace BCM control unit.
No > Maintenance or replace harness.