Page 527 - Workshop Manual - Tunland (2017)
P. 527

DIAGNOSTICS - LIGHTING SYSTEM                            04-389

                                                           (c)    Disconnect the connector C036 of BCM
                                                                  control unit.







                                                                                                                     04





                                                 ftwxd041026

                                                           (d)    Measure the resistance as per the values
                                                                  given in the table below
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)
                             C036
                                                            Multimeter connection          Standard value
                        16  15  14 13  12  11 10  9  8 7  6 5  4  3 2  1
                        32  31  30  29  28  27  26  25  24  23  22  21  20 19  18  17
                                                              C036(E6)-C008(12)                 < 2 Ω

                             C008

                    10  9  8  7  6  5  4  3  2  1
                    20  19  18  17  16  15  14 13 12  11



                                                 ftwxd041004

                 Check whether the result is normal?
                 Yes> Replace BCM control unit.

                 No > Maintenance or replace harness.