                                                           (e)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                                            Multimeter connection          Standard value
                                                                                                                     04
                     C036                                     R7(5)-A016(1)
                                                                                                < 2 Ω
                                                              R7(5)-A005(1)




                                       C040









                                                 ftwxd041391

                 Check whether the result is normal?

                 Yes> go to step 5
                 No > Maintain or replace the harness


                 5 .    Check the harness and connectors (front fog lamp - ground)
                 (a)    Ignition Switch: OFF.
                 (b)    Unplug the front fog lamp relay R7.

                                                           (c)    Disconnect the left front fog lamp connector
                                                                  A016.
                                                           (d)    Disconnect the right front fog lamp connector
                                                                  A005.