04-396                         DIAGNOSTICS - LIGHTING SYSTEM

           Check whether the result is normal?

           Yes> go to step 8
           No > Replace the combination switch.

           8 .    Check the harness and connectors (combination switch - ground)

      04     (a)  Ignition Switch: OFF.

                                                      (b)    Disconnect the connector C008 of
                                                             combination switch (lamplight switchover).














                                           ftwx641019


                                                      (c)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

                                                       Multimeter connection          Standard value
                                           C008
                                                          C008 (7) - ground               < 2 Ω









                                           ftwxd041396

           Check whether the result is normal?

           Yes> go to step 9
           No > Maintenance or replace harness.

           9 .    Check the wiring harness and connectors (BCM controlling unit - combination
                  switch)
           (a)    Ignition Switch: OFF.