Page 533 - Workshop Manual - Tunland (2017)
P. 533
DIAGNOSTICS - LIGHTING SYSTEM 04-395
(d) Measure the electrical resistance based on
the value in the following form.
Standard electrical resistance (check
whether there existent an open circuit)
Multimeter connection Standard value
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
C035 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 04
R7(2)- C035(D16) < 2 Ω
2
4 5 3 R7
1
ftwxd041003
Check whether the result is normal?
Yes> go to step 7
No > Maintain or replace the harness
7 . Check the combination switch (lamplight switchover)
(a) Ignition Switch: OFF.
(b) Disconnect the connector C008 of
combination switch (lamplight switchover).
ftwx641019
(c) Check the combination switch (lamplight
switchover)
Standard voltage
Connecting
Specified
Conditions pins of
value
multimeter
Turn off the fog
7-8 ≥ 1 MΩ
lamp switch
Turn on the fog
7-8 < 2 Ω
lamp switch