Page 533 - Workshop Manual - Tunland (2017)
P. 533

DIAGNOSTICS - LIGHTING SYSTEM                            04-395

                                                           (d)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                                            Multimeter connection          Standard value
                                     16  15  14 13  12  11 10  9  8 7  6 5  4  3 2  1
                              C035   32  31  30  29  28  27  26  25  24  23  22  21  20 19  18  17                   04
                                                            R7(2)- C035(D16)                    < 2 Ω





                       2
                       4  5  3 R7
                       1
                                                 ftwxd041003


                 Check whether the result is normal?
                 Yes> go to step 7
                 No > Maintain or replace the harness


                 7 .    Check the combination switch (lamplight switchover)
                 (a)    Ignition Switch: OFF.

                                                           (b)    Disconnect the connector C008 of
                                                                  combination switch (lamplight switchover).














                                                 ftwx641019

                                                           (c)    Check the combination switch (lamplight
                                                                  switchover)
                                                                  Standard voltage

                                                                                Connecting
                                                                                                   Specified
                                                              Conditions          pins of
                                                                                                     value
                                                                                multimeter

                                                            Turn off the fog
                                                                                     7-8            ≥ 1 MΩ
                                                              lamp switch
                                                            Turn on the fog
                                                                                     7-8             < 2 Ω
                                                              lamp switch
   528   529   530   531   532   533   534   535   536   537   538