Page 535 - Workshop Manual - Tunland (2017)
P. 535
DIAGNOSTICS - LIGHTING SYSTEM 04-397
(b) Disconnect the connector C008 of
combination switch (lamplight switchover).
04
ftwx641019
(c) Disconnect the connector C036 of BCM
control unit.
ftwxd041026
(d) Measure the electrical resistance based on
the value in the following form.
Standard electrical resistance (check
whether there existent an open circuit)
Multimeter connection Standard value
C036 C036(E9)-C008(8) < 2 Ω
C008
ftwxd041397
Check whether the result is normal?
Yes> Replace BCM control unit.
No > Maintenance or replace harness.