DIAGNOSTICS - LIGHTING SYSTEM                            04-409

                                                           (f)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)
                              C034
                                                            Multimeter connection          Standard value
                                                                                                                     04
                                                               C034(C2)- A010
                                                                      (3)

                                                               C034(C2)- B010                   < 2 Ω
                                                                      (5)
                                                            C034(C2)- J003(3)









                                                 ftwxd041400

                 Check whether the result is normal?

                 Yes> go to step 5
                 No > Maintenance or replace harness.


                 5 .    Check the harness and connectors (left turn light - ground)