Page 552 - Workshop Manual - Tunland (2017)
P. 552

04-414                         DIAGNOSTICS - LIGHTING SYSTEM

                                                      (d)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

                                                       Multimeter connection          Standard value
      04
                                                        C036(E11) - C008
                                         C036                                             < 2 Ω
                                                               (17)





                                       C008









                                            ftwxd041401

           Check whether the result is normal?

           Yes> Replace BCM control unit.
           No > Maintenance or replace harness.
   547   548   549   550   551   552   553   554   555   556   557