Page 549 - Workshop Manual - Tunland (2017)
P. 549
DIAGNOSTICS - LIGHTING SYSTEM 04-411
(f) Measure the electrical resistance based on
the value in the following form.
Standard electrical resistance (check
whether there existent an open circuit)
Multimeter connection Standard value
04
A010 (2) - ground
B010 (1) - Ground < 2 Ω
J003 (2) - ground
Check whether the result is normal?
Yes> go to step 6
No > Maintenance or replace harness.
6 . Check the combination switch (lamplight switchover)
(a) Ignition Switch: OFF.
(b) Disconnect the connector C008 of
combination switch (lamplight switchover).
ftwx641019