Page 549 - Workshop Manual - Tunland (2017)
P. 549

DIAGNOSTICS - LIGHTING SYSTEM                            04-411

                                                           (f)    Measure the electrical resistance based on
                                                                  the value in the following form.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                                            Multimeter connection          Standard value
                                                                                                                     04
                                                               A010 (2) - ground
                                                               B010 (1) - Ground                < 2 Ω

                                                                J003 (2) - ground
















                 Check whether the result is normal?

                 Yes> go to step 6
                 No > Maintenance or replace harness.

                 6 .    Check the combination switch (lamplight switchover)

                 (a)    Ignition Switch: OFF.

                                                           (b)    Disconnect the connector C008 of
                                                                  combination switch (lamplight switchover).














                                                 ftwx641019
   544   545   546   547   548   549   550   551   552   553   554