Page 550 - Workshop Manual - Tunland (2017)
P. 550

04-412                         DIAGNOSTICS - LIGHTING SYSTEM

                                                      (c)    Check the combination switch (lamplight
                                                             switchover)
                                                             Standard resistance:

                                                                           Multimeter
                                                                                             Specified
                                                        Conditions        connection
      04                                                                     stitch             value
                                                       Turn off the left
                                                                              17-19           ≥ 1 MΩ
                                                         turn switch

                                                       Turn on the left
                                                                              17-19            < 2 Ω
                                                         turn switch





           Check whether the result is normal?
           Yes> go to step 7
           No > Replace the combination switch.


           7 .    Check the harness and connectors (combination switch - ground)
           (a)    Ignition Switch: OFF.

                                                      (b)    Disconnect the connector C008 of
                                                             combination switch (lamplight switchover).














                                           ftwx641019

                                                      (c)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

                                            C008
                                                       Multimeter connection          Standard value
                                                         C008 (19) - ground               < 2 Ω










                                           ftwxd041390
   545   546   547   548   549   550   551   552   553   554   555