Page 628 - Workshop Manual - Tunland (2017)
P. 628
04-490 DIAGNOSTICS - ASSEMBLY INSTRUMENT
Diagnostic steps
1 . Check whether the signal circuit of vacuum alarm indicating lamp is short circuit
(a) Ignition Switch: OFF.
(b) Disconnect the connector A008of the vacuum
04 alarm.
(c) Ignition Switch: ON.
Check whether the vacuum alarm indicating lamp is off.
Yes > Change the vacuum alarm.
No> go to step 2
2 . Check whether the signal circuit of vacuum alarm indicating lamp is short circuit
(a) Ignition Switch: OFF.
(b) Disconnect the connector C013 of
combination instrument.
ftwx831083