04-490                       DIAGNOSTICS - ASSEMBLY INSTRUMENT

           Diagnostic steps

           1 .    Check whether the signal circuit of vacuum alarm indicating lamp is short circuit

           (a)    Ignition Switch: OFF.

                                                      (b)    Disconnect the connector A008of the vacuum
      04                                                     alarm.
                                                      (c)    Ignition Switch: ON.




















           Check whether the vacuum alarm indicating lamp is off.

           Yes > Change the vacuum alarm.
           No> go to step 2


           2 .    Check whether the signal circuit of vacuum alarm indicating lamp is short circuit
           (a)    Ignition Switch: OFF.

                                                      (b)    Disconnect the connector C013 of
                                                             combination instrument.



















                                            ftwx831083