Page 629 - Workshop Manual - Tunland (2017)
P. 629

DIAGNOSTICS - ASSEMBLY INSTRUMENT                           04-491

                                                           (c)    Use a multimeter to measure the resistance
                                                                  between pin 1 of connector A008 of vacuum
                                                                  alarm and ground.
                                                                  Standard resistance (check whether there
                             A008
                                                                  is short circuit)
                                                            Multimeter connection          Standard value            04
                             1  2
                                                              A008 (1) - Grounding             ≥ 1 MΩ







                                                 ftwxd041299


                 Check whether the result is normal?
                 Yes> replace combination instrument assembly.
                 No > Repair the to-ground short circuit of signal circuit between the pin 1 of connector
                 C013 of the vacuum alarm and the pin 9 of connector C013 of the combination
                 instrument.


                 3 .    Check whether the signal circuit of vacuum alarm indicating lamp is of open
                        circuit
                 (a)    Ignition Switch: OFF.

                                                           (b)    Disconnect the connector A008 of the vacuum
                                                                  alarm.
                                                           (c)    Ignition Switch: ON.
   624   625   626   627   628   629   630   631   632   633   634