DIAGNOSTICS - ENGINE CONTROL SYSTEM                          04-141

                                                                                                                     04
                 3 .    Check starting motor relay R3
                 (a)    Ignition switch: OFF.
                 (b)    Disconnect the battery negative cable.
                 (c)    Open the engine compartment relay box and pull out the starting motor relay R3.
                 (d)    Check whether the starting motor relay R3 is good or not.

                 Is the inspection result normal?
                 YES>To step 4.

                 NO> Replace starting motor relay R3

                 4 .    Replace starting motor relay R3
                 (a)    Ignition switch: OFF.
                 (b)    Disconnect the battery negative cable.
                 (c)    Pull out starting motor relay R3.
                 (d)    Disconnect the starting motor connector K006.
                 (e)    Connect the battery negative cable.
                 (f)    Ignition switch: ON.

                                                           (g)    Use a multimeter to measure the voltage
                                                                  between the pin 1, 3 of starting motor relay
                                                                  R3 and the ground respectively.

                                                                  Standard voltage
                                                            Multimeter connection          Standard value
                                                                       pin

                                                                R3(1)-ground                Battery voltage

                                                                R3(3)-ground                Battery voltage








                                                           (h)    Use a multimeter to measure the resistance
                                                                  between the pin 5 of starting motor relay R3
                                                                  and the pin 1 of starting motor connector
                                                                  K006.
                                                                  Standard resistance

                                                            Multimeter connection
                                                                                           Standard value
                                                                       pin
                                                              R3(5)- K006(1)                    <2 Ω