  VetBooks.ir  6.2.6  OXIDATION REDUCTION POTENTIAL (ORP) METHOD




            ORP can be an important method for measuring the general oxidative status
            of meat products. The ORP method does not measure specific products of
            oxidation. It can be used for evaluating oxidation inhibitors (Fig. 6.26).













                                         Platinum REDOX electrode






                                     Meat homogenate
                                       (buffered)
            FIGURE 6.26  Oxidation reduction potentials (ORPs) can be used to broadly measure the
            oxidative status of meat products. Negative values for ORPs indicate reducing (favorable)
            environment. Diagram by Tom Jones.

               The ORP method is a direct measurement of the all the oxidized and
            non-oxidized compounds in the meat sample (Vahabzadeh, 1986). The elec-
            trical potential measured is related to the concentration of oxidized and non-
            oxidized species through the Nernst equation.

                          0.059
                  E =   E +  n  log 10  [   oxidized and nonoxidized species ]  (6.15)
                       o

            where E is the reading taken at the potentiometer in mV,
            E  is reference electrode in mV,
             o
            0.059 is a constant calculated by mathematically combining the universal
            gas constant, temperature (K), Faraday’s constant,

            n is the number of electrons (unknown) involved in the oxidation reduction
            process, since meat systems have dilute ionic concentrations (or activities)
            n can be ignored.