Page 149 - Testing Electronic Components
P. 149

touching the Anode pin) and you will notice the meter’s pointer will kick
                   as shown at the picture (low resistance).
























                                                                  Removing the black probe from
                                                                  the GATE pin (the black probe
                                                                  still touching the Anode pin)
                                                                  you would noticed that the
                                                                  resistance continues to be there
                                                                  (low resistance). This is due to
                                                                  the conduction of SCR as the
                                                                  meter battery is usually able to
                                                                  supply current more than the
                                                                  holding current.

                                                                  If at this stage you removed the
                                                                  black probe from the Anode
                                                                  pin and connect it back, the
                                                                  pointer will dropped back to
                                                                  infinity (high resistance). If the
                                                                  SCR could hold the resistance
                                                                  then the SCR is considered
                                                                  good. If it can’t hold then the
                   SCR is faulty.

                   Conclusion- Practice testing SCR more often to see how’s the result like.
                   Try some different part numbers and power SCR-and if the resistance
                   don’t hold using X1 ohm, you may try X10 ohm and etc.