Page 6 - FQ10571.RexConLLC.WI.-For-ReadyMixConcreteFacility.DC7000 wOption 2000 GalTank
P. 6

Page No. 3
                                                                                Proposal No. Q10571
                                                                                Date:  September 13, 2017

                            5.      Prepiped and prewired pilot gas train assembly including:

                                    5.1    Pilot solenoid valve.
                                    5.2    Pilot pressure regulator.
                                    5.3    Pilot shutoff valve.
                                    5.4    Spark ignition assembly.
                                    5.5    Stable blast flame assembly.

                            6.      System mounted U. L. Labeled control panel including:

                                    6.1    NEMA-12 enclosure.
                                    6.2    Electronic temperature controller.
                                    6.3    Three (3) flush mounted digital thermometers indicating inlet
                                           water, outlet water and stack temperatures.
                                    6.4    Indicator light display panel.
                                    6.5    Audible alarm for water status (Bell).
                                    6.6    Numbered terminal strip for ease of hook-up.

                            7.      Microprocessor based burner management control system (U.L. Listed)
                                    including:

                                    7.1    Flame monitor.
                                    7.2    U.V. flame scanner.
                                    7.3    Diagnostic status display.
                                    7.4    Burner control panel.
                                    7.5    Audible alarm of burner status (Siren).

                            8.      Full thermostatic modulation control system including:

                                    8.1    Temperature sensors.
                                    8.2    Modulating drive motor.

                            9.      One (1) Sight glass to view combustion.


               One (1)      High Capacity Centrifugal Transfer Type Water Pump, capable of nominally
                            pumping 190 GPM at 70 ft. water T.D.H. and including:

                            1.      Cast iron case.
                            2.      Bronze fitted with mechanical seals.
                            3.      Built together type configuration.
                            4.      Totally enclosed fan cooled electric motor, 7-1/2 Hp.
   1   2   3   4   5   6   7   8   9   10   11