Page 7 - FQ10571.RexConLLC.WI.-For-ReadyMixConcreteFacility.DC7000 wOption 2000 GalTank
P. 7

Page No. 4
                                                                                Proposal No. Q10571
                                                                                Date:  September 13, 2017

               One (1)      Set of Pump Controls, Including:

                            1.      Starter with NEMA Type 1 enclosure and overloads mounted on heater.
                            2.      Selector switch, mounted on the control panel.
                            3.      Starter coil and selector switch are prewired.
                            4.      Pressure gauge.
                            5.      Check valve.

               One (1)      Hot Water Transfer Assembly, Including:

                            1.      Manual throttling valve.  (Set at average rate).
                            2.      High pumping rate water valve.  (Solenoid operated).
                                    2.1    Anti-hammer diaphragm seat.

               One (1)      Water Level Control Sensor Assembly, Including:

                            1.      Five (5) level sensing probes.
                            2.       One (1) set of gauge cocks with plastic sight glass.
                            3.      Water wall level sensor.

               One (1)      Water Flow Rate Assembly, Including:

                            1.      One (1) pressure gauge.  (Setting flow rate).
                            2.      One (1) pressure actuated switch.  (Confirm flow and initiate firing).

               One (1)      Water Make-Up Valve, Including:

                            1.      Average rate solenoid operated valve.

                                    1.1    Anti-hammer diaphragm seat.

               One (1)      Outer Wall Temperature Sensor

               One (1)      Water Recirculation Assembly Including:

                            1.      Temperature actuated switch - (Remotely mounted in hot water tank).
                            2.      Recirculation water valve - solenoid operated.
                                    2.1    Anti-hammer diaphragm seat.
   2   3   4   5   6   7   8   9   10   11   12