               One (1)      Safety Monitor Including:

                            1.      Temperature actuated switch - electrical signaling.

                            2.      Safety shut-down features are included on the Ludell water heaters that
                                    shut the heater down, if the stack temperature, water wall level, or wall
                                    temperature exceed normal operating levels.

                            3.      Automatic refire is a feature of the heater that is operational when all
                                    heater safety requirements are satisfied.  A safety shut-down will require
                                    the heater to be restarted manually in accordance with the requirements of
                                    U.L.

               One (1)      Integral 520 Gallon Storage Tank, Type 304 Stainless Steel:

                            1.      Sight gauge and overflow.
                            2.      Necessary fittings for Ludell system.
                            3.      Tank dimensions of 60” long x 48” wide x 42” high.

               One (1)      Set of Drawings Including:

                            1.      Piping schematic.
                            2.      Wiring schematic.

               One (1)      Operating and Maintenance Manual

               Note I - Ludell Field Service

                       Ludell has included in its proposal the services of our field engineer to inspect the
                       equipment for proper installation, adjust controls to factory standards, verify
                       performance guarantees, and instruct your personnel on the equipment features,
                       maintenance and operational use.  It is necessary to contact the Ludell Service
                       Department two (2) weeks prior to your planned equipment start-up.  Service is
                       scheduled to begin and end during the normal work week (Monday – Friday).  Normal
                       workday is 8 hours; any overtime will be billed separately.  Weekend travel and/or
                       short term notice start-up service will be charged at additional cost.  NOTE:  If
                       additional  trips and service are needed, they will be billed on a per diem basis, plus
                       travel and living expenses at cost.

               Note II - Certified Inspection

                            All Ludell Direct Contact Water Heaters are factory inspected.