P. 280

INSULPRO PAINTS
                                                                                                       11-19-15

                       MOISTURE:  Test all surfaces prior to painting using a moisture meter.  Do not
                       apply paint unless moisture levels of the substrate are below the following:

                       Moisture content for masonry and stucco must not exceed 17%
                       Moisture content for exterior wood must not exceed 12%
                       Moisture content for interior wood must not exceed 8%

               Part 3 – PAINTING SCHEDULE: WOOD AND METAL

                   A.  Prepare, paint and finish all surfaces specified and agreed upon.

                   B.  Provide paint finishes of even uniform color, free from cloudy or mottled
                       appearance.  Properly correct all non-complying work to the satisfaction of the
                       Owner’s representative and the representative of the paint manufacturer.

                   C.  Paint Application Finish Schedule:

                       1.  Wood: Beams above garage doors, wood trim between windows.

                          Apply first coat Super Block primer, followed by one coat of Flex Patch.
                          1  Coat:                 2585 Super Block Primer
                            st
                          2  Coat:                        40253 Ultra Kote
                            nd

                          Note:  Apply Ultra Kote to a total dry mil thickness of 4 to 5 dry mils.

                       2.  Metal:  Enamel surfaces:  Wrought iron, Metal garage doors and doors.

                          Spot prime repairs and patching with 561 Acrylic Metal Prime
                            st
                          1  Coat (Applied to 1.5 mils DFT)       5750 Weatherguard 100% Acrylic with
                                                                  Urethane Semi-gloss Industrial Latex
                                                                  Enamel
                          2  Coat (If necessary):                 5750 Weatherguard 100% Acrylic with
                            nd
                                                                  Urethane Semi-gloss Industrial Latex
                                                                  Enamel

                          Note:  Apply material at manufacturer’s recommended thickness of 4.4 mils
                          WFT or 1.5 mils DFT per coat to achieve best hide, durability, and protection.


                          3.   Metal:  Galvanized Gutters and Downspouts, Flashing,, Decorative Chimney
                          Caps, scuppers, Flashings, Metal Meter Boxes,
                          Spot prime repairs and patching with 561 Acrylic Metal Prime
                          1  Coat:                         2790 Ultra Prime
                            st
                            nd
                          2  Coat                             40253 Ultra Kote
                          Note:  Apply material at manufacturer’s recommended dry thickness
                                Of 4 to 5 dry mils.


                                                       Page 14 of 15