Page 25 - Parker - General Technical
P. 25
4300 Catalog General Technical
Inch Tube Pressure Ratings P
Return
To
Index
Inch Tubes* Inch Tubes*
Design Pressure Design Pressure
Stainless Stainless
Tube Wall Tube Steel Tube Wall Tube Steel
O.D. Thick. I.D. Pressure Steel 304 & 316, Copper O.D. Thick. I.D. Pressure Steel 304 & 316, Copper
(in.) (in.) (in.) C-1010 C-1021 4130 HSLA K or Y (in.) (in.) (in.) C-1010 C-1021 4130 HSLA K or Y
0.125 0.010 0.105 1,900 2,550 3,200 1,000 0.625 0.058 0.509 2,250 3,000 3,750 1,200
0.125 0.020 0.085 4,100 5,500 6,850 2,200 0.625 0.065 0.495 2,550 3,400 4,250 1,350
0.125 0.028 0.069 5,950 7,950 9,950 3,150 0.625 0.083 0.459 3,350 4,450 5,600 1,750
0.125 0.035 0.055 7,550 10,100 12,650 4,050 0.625 0.095 0.435 3,900 5,200 6,500 2,050
0.188 0.010 0.168 1,250 1,650 2,100 650 0.625 0.109 0.407 4,500 6,050 7,550 2,400
0.188 0.020 0.148 2,600 3,500 4,400 1,400 0.625 0.120 0.385 5,050 6,700 8,400 2,700
Table T17 — Design Stress Values 0.188 0.028 0.132 3,800 5,050 6,350 2,000 0.625 0.134 0.357 5,700 7,600 9,500 3,000
0.188 0.035 0.118 4,850 6,500 8,150 2,600 0.750 0.035 0.680 1,050 1,450 1,800 550
0.188 0.049 0.090 7,000 9,400 11,750 3,750 0.750 0.049 0.652 1,550 2,050 2,600 800
0.250 0.020 0.210 1,900 2,550 3,200 1,000 0.750 0.058 0.634 1,850 2,450 3,100 1,000
0.250 0.028 0.194 2,750 3,700 4,650 1,450 0.750 0.065 0.620 2,100 2,800 3,500 1,100
0.250 0.035 0.180 3,350 4,750 5,900 1,900 0.750 0.083 0.584 2,750 3,650 4,550 1,450
0.250 0.049 0.152 5,150 6,900 8,600 2,750 0.750 0.095 0.560 3,150 4,250 5,300 1,700
0.250 0.058 0.134 6,200 8,300 10,350 3,300 0.750 0.109 0.532 3,700 4,950 6,150 1,950
0.250 0.065 0.120 7,000 9,350 11,700 3,750 0.750 0.120 0.510 4,100 5,500 6,850 2,200
0.250 0.083 0.084 8,950 11,950 14,900 4,750 0.750 0.134 0.482 4,650 6,200 7,750 2,450
0.313 0.020 0.273 1,500 2,000 2,500 800 0.750 0.148 0.454 5,200 6,950 8,650 2,750
0.313 0.028 0.257 2,150 2,900 3,600 1,150 0.750 0.188 0.374 6,750 9,000 11,250 3,600
0.313 0.035 0.243 2,750 3,700 4,600 1,450 0.875 0.035 0.805 900 1,200 1,550 500
0.313 0.049 0.215 4,000 5,350 6,700 2,150 0.875 0.049 0.777 1,300 1,750 2,200 700
0.313 0.058 0.197 4,850 6,450 8,100 2,550 0.875 0.058 0.759 1,550 2,100 2,600 800
0.313 0.065 0.183 5,500 7,350 9,150 2,900 0.875 0.065 0.745 1,750 2,350 2,950 950
0.313 0.083 0.147 7,150 9,550 11,950 3,800 0.875 0.083 0.709 2,300 3,100 3,850 1,200
0.313 0.095 0.123 8,200 10,950 13,700 4,350 0.875 0.095 0.685 2,650 3,600 4,500 1,400
0.375 0.020 0.335 1,250 1,650 2,100 650 0.875 0.109 0.657 3,100 4,150 5,200 1,650
0.375 0.028 0.319 1,800 2,400 3,000 950 0.875 0.120 0.635 3,450 4,650 5,800 1,850
0.375 0.035 0.305 2,250 3,050 3,800 1,200 0.875 0.134 0.607 3,900 5,250 6,550 2,100
0.375 0.049 0.277 3,300 4,400 5,500 1,750 0.875 0.148 0.579 4,350 5,850 7,300 2,300
0.375 0.058 0.259 3,950 5,300 6,600 2,100 1.000 0.035 0.930 800 1,050 1,350 400
0.375 0.065 0.245 4,500 6,000 7,500 2,400 1.000 0.049 0.902 1,150 1,500 1,900 600
0.375 0.083 0.209 5,900 7,850 9,850 3,150 1.000 0.058 0.884 1,350 1,800 2,300 700
0.375 0.095 0.185 6,800 9,100 11,400 3,650 1.000 0.065 0.870 1,550 2,050 2,550 800
0.375 0.109 0.157 7,850 10,500 13,150 4,200 1.000 0.083 0.834 2,000 2,650 3,350 1,050
0.500 0.028 0.444 1,300 1,750 2,200 700 1.000 0.095 0.810 2,300 3,100 3,850 1,200
0.500 0.035 0.430 1,650 2,200 2,800 850 1.000 0.109 0.782 2,700 3,600 4,500 1,400
0.500 0.049 0.402 2,400 3,200 4,000 1,250 1.000 0.120 0.760 3,000 4,000 5,000 1,600
Table T19 — Severity of Service Design and Derating Factors
0.500 0.058 0.384 2,900 3,850 4,800 1,500 1.000 0.134 0.732 3,350 4,500 5,650 1,800
0.500 0.065 0.370 3,250 4,350 5,450 1,750 1.000 0.148 0.704 3,750 5,050 6,300 2,000
0.500 0.083 0.334 4,300 5,700 7,150 2,250 1.000 0.156 0.688 4,000 5,350 6,700 2,100
0.500 0.095 0.310 4,950 6,650 8,300 2,650 1.000 0.188 0.624 4,900 6,550 8,200 2,600
0.500 0.109 0.282 5,800 7,750 9,700 3,100 1.000 0.220 0.560 5,850 7,800 9,750 3,100
0.500 0.120 0.260 6,450 8,600 10,750 3,400 1.250 0.049 1.152 900 1,200 1,500 450
0.500 0.134 0.232 7,250 9,650 12,100 3,850 1.250 0.058 1.134 1,050 1,450 1,800 550
0.500 0.148 0.204 8,000 10,700 13,350 4,250 1.250 0.065 1.120 1,200 1,600 2,050 650
0.500 0.188 0.124 9,900 13,250 16,550 5,300 1.250 0.083 1.084 1,550 2,100 2,650 800
0.625 0.028 0.569 1,050 1,400 1,750 550 1.250 0.095 1.060 1,800 2,450 3,050 950
0.625 0.035 0.555 1,300 1,750 2,200 700 1.250 0.109 1.032 2,100 2,800 3,550 1,100
0.625 0.049 0.527 1,900 1,900 1,900 1,900 1.250 0.120 1.010 2,350 3,150 3,900 1,250
Table T20 — Inch Tube Pressure Ratings
*See Table T8 for tube specifications.
Dimensions and pressures for reference only, subject to change.
T25 Parker Hannifin Corporation
Tube Fittings Division
Columbus, Ohio
http://www.parker.com/tfd