Page 15 - Parker - L90LS Mobile directional control valve
P. 15

Catalogue HY17-8504/UK                            Mobile Directional Control Valve
            Inlet Section                                     L90LS


            Pressure setting [17]
            Pressure setting for PA1 [16]                       Pressure setting for PS [16]
                   The direct-acting pressure relief valve, PA1, is delivered   The pilot-operated pressure relief valve, PS, is adjust-
                   with a fixed setting. The following standard settings are   able from 50 to 320 bar. The valve can, however, be
                   available:                                         delivered with a fixed setting according to the value
                   Pressure setting in bar: 63, 80, 100, 125, 140, 160, 175,   specified.
                   190, 210, 230, 240, 250, 260, 280, 300 and 320.

            ∆p (bar)  Pressure relief characteristics           ∆p (bar)  Pressure relief characteristics

            400                                                 400



            300                                                 300



            200                                                 200



            100                                                 100



              0                                                   0
                0        50        100        150       200        0         50         100       150        200
                                                      q (l/min)                                           q (l/min)
            PA1 - Direct acting pressure relief valve.          PS - Pilot-operated pressure relief valve.

















            Differential pressure limiter, PLS [18]
            20-38   Function which maximize the pressure difference
                   between the pump pressure and the load signal from
                   the spool sections in inlet section AS [15]. The differen-
                   tial pressure must be set slightly higher in the inlet than
                   in the pump regulator itself, approx. 5-8 bar.















                                                                PLS - limiting function which maximise the differential pressure
                                                                between the pump pressure and the load signal.