Page 9 - Eaton - Gas/Liquid separators
P. 9
Gas/Liquid Separation Fabricated Construction
Gas/Liquid Separators
Type TS
Vertical
Fabricated
Construction
• Custom Sizes FEATURES
• Designed for High Liquid Loading Applications
• Threaded, Flanged • High Efficiency Over Wide Flow Range
or Socket Weld • No Required Maintenance
• Removes 99% of Liquid and Solid Entrainment
• Carbon Steel Particles Larger Than 10 Microns
or Stainless Steel • Gas, Steam, or Air Applications
OPTIONS
• ASME UM or U Code Stamp (Carbon Steel and
Stainless Steel Models)
• Support Legs
High Efficiency – cases, there is a liquid where the exclusive Eaton
No Maintenance holdup requirement where Vortex Containment Plate
instrumentation is provided for (VCP) ensures that they can’t
The Eaton Type TS Gas/Liquid controlling the level of the be re-entrained. The clean,
Separator automatically liquid in the reservoir of the dry flow is then directed to
removes 99% of all liquid and vessel. Some common the outlet by the VCP. This
solid entrainment particles 10 applications include upstream eliminates the need for
microns in size or larger from of gas turbines, absorption expensive, delicate baffles
air, gas, and steam processes. towers, steam generator used in ordinary separators.
And it does so with no moving outlets and gas scrubbers.
parts to wear out and with no
required maintenance. Fabricated Construction
Exclusive Design
The Type TS Separator is
Applications Moisture-laden gas enters available in fabricated carbon
the inlet of the separator, steel, stainless steel, or other
The Eaton Type TS Gas/Liquid where it is deflected in a alloy construction with socket
Separator is designed for centrifugal downward motion. weld, threaded or 150 lb.,
applications where heavier The entrained solids and 300 lb., or 600 lb. flange
than normal liquid loading moisture droplets are connections. Depending on
causes a “slugging” problem. separated out by a reduction in the separator size, liquid
These applications are widely velocity. Separated liquid and holdup capacities range from
found in refineries and solids fall into a reservoir 0.19 cu. ft. to 32.64 cu. ft.,
chemical plants. In many
or larger should the application
require. The separators can
be furnished with an ASME
Code Stamp as an option.
Optional integral support legs
can also be specified.