Page 10 - Parker - OSP-P Pneumatic Rodless Cylinders and Linear Guides
P. 10
Catalog 0980 OSP-P Pneumatic Rodless Cylinders and Linear Guides
examples Control examples for OSP-P
A
Circuit diagram for end Circuit diagram for end The optional integrated VOE Valves offer optimal control,
of stroke application. of stroke application. and allow accurate positioning of intermediate positions and
Intermediate positioning is Intermediate positioning is the lowest possible speeds.
also possible. also possible.
The cylinder is controlled The cylinder is controlled
by two 3/2-way valves by a 5/3-way valve (middle
(normally open). The position pressurized).
speed can be adjusted The speed can be adjusted
independently for both independently for both
directions. directions.
Fast/Slow speed cycle control with pneumatic brake for The combination of an OSP-cylinder with the passive
accurate positioning at high velocities. Additional 3/2-way MULTIBRAKE as shown here, allows accurate positioning
valves with adjustable throttle valves at the exhaust of the and safety in case of loss of pneumatic air pressure.
standard directional control valves for two displacement
speeds in each direction of the piston’s travel.
The valve controlling the brake is activated after the slow
speed cycle is activated.
A8 Parker Hannifin Corporation
Parker-Origa
ORIGA Glendale Heights, Illinois
www.parker.com/pneu/rodless