Page 21 - Gefran - Lift control systems
P. 21
Gefran Spa - Drive & Motion Control Unit • www.gefran.com 21
Connessione contactorless
Contactorless* connections • Branchement sans utilisation de contacteurs* • Anschlüss* ohne Schütze • Conexiones sin uso de contactores*
(*) Referring to the power contacts between drive and motor.
Schema di un sistema lift conforme a prEN81-20 5.9.2.5.3 d, senza utilizzo di contattori e funzione di sicurezza integrata STO (EN61800-5-2- SIL3).
Diagram of a lift system complying with EN81-20 5.9.2.5.3 d, without contactors and STO integrated safety function (EN61800-5-2- SIL3).
Schéma d’un système d’élévation conforme à la norme prEN81-20 5.9.2.5.3 d, sans utilisation de contacteurs et fonction de sécurité intégrée STO (EN61800-5-2- SIL3).
Schema eines Aufzugssystems gemäß prEN81-20 5.9.2.5.3 d ohne Einsatz von Schützen und integrierter Sicherheitsfunktion STO (EN61800-5-2- SIL3).
Diagrama de un sistema lift, de acuerdo con la normativa prEN81-20 5.9.2.5.3 d, sin uso de contactores y función de seguridad integrada STO (EN61800-5-2- SIL3).
Asynchronous motor 3 Phase Mains
SYSTEM CONTROL UNIT K4 (*) CONTACTORLESS
OK (*)
Contactor ADL300
check-up
F1
Commands
1 3 5
K1M (optional)
2 4 6
OPTIONAL
L1
AC
BREAKING
RESISTORS
L1 L2 L3 PE KEYPAD / DCP PC L SH H Internal Keypad R-ADL EXP-IO
U1 V1 W1 CAN BRK CNT EN ILIM n=0 AL
OPTIONAL BR1 CAN
RS232
Prg
BR2 Enter
ADL300.-...-4 (size 1, 2 and 3)
C P-ADL CONTACTORLESS
EXP-ENC
L1 CONTACTOR CONTACTOR
DC D OK (*) RUN BRAKE DRIVE OK
EM DI8 DI7 DI6 DI5 DI4 DI3 DI2 DI1 ENHW DICM 0VOUT 24VOUT
U2 V2 W2 SAFETY EN+ SAFETY EN- SAFETY OK1 SAFETY OK2 AGL50
T1 T2 T3 PE PE 1 2 3 4 5 6 7 8 9 10 11 12 50 51 52 53 54 55 56 57 Emergency
MltSpd S1 MltSpd S0 Emergency mode StartRevCmd StartFwdCmd Safety Failure L1
chain
K2M K4 K3M
TRAFO
A1 A1 A1
BR A2 A2 A2
K4 (*)
K2M
K3M BRAKE K2M K3M BR
M
3 ~
(*): K4 and CONTACTORLESS OK must be checked by control unit
- PAR 1416 Dig output 4X src programmed as 1024 Enable cmd mon
- PAR 1436 Dig out 4X inversion = ON
AVRy
Synchronous motor 3 Phase Mains
SYSTEM CONTROL UNIT K4 CONTACTORLESS
OK
Contactor
check-up
F1
Commands
1 3 5
K1M (optional)
2 4 6
OPTIONAL
L1
AC
BREAKING
RESISTORS
L1 L2 L3 PE KEYPAD / DCP PC L SH H Internal Keypad R-ADL EXP-IO
U1 V1 W1 CAN BRK CNT EN ILIM n=0 AL
OPTIONAL BR RS232 CAN
Prg
C Enter
ADL300.-...-4 (size 1, 2 and 3) AFE200
C1 P-ADL CONTACTORLESS
EXP-ENC
L1
D
DC OK (*) RUN BRAKE DRIVE
EM SAFETY EN+ SAFETY EN- SAFETY OK1 SAFETY OK2 DI8 DI7 DI6 DI5 DI4 DI3 DI2 DI1 ENHW DICM 0VOUT 24VOUT CONTACTOR CONTACTOR OK
U2 V2 W2
T1 T2 T3 PE PE 1 2 3 4 5 6 7 8 9 10 11 12 50 51 52 53 54 55 56 57
Contactorless Emergency mode StartRevCmd StartFwdCmd Safety Emergency
Failure
Safety
L1
chain
chain
K4 Enable BrakeFbk MltSpd S2 MltSpd S1 MltSpd S0
K2M K4
TRAFO K2M
K3M K3M A1 A1 A1
K3M
BR A2 A2 A2
K3M
K2M
AppEnDix
K3M BRAKE K2M K3M BR
M
3 ~
FBR K3M interlocked contacts
PAR 11088 Contactorless enable must be turn On to configure
CONTACTORLESS OK and CONTACTORLESS ENABLE I/O