Page 32 - Paker - Medium Duty Hydraulic Cylinders
P. 32
Catalog HY08-1130-4/NA Medium Duty Hydraulic Cylinders
Mounting Information – 1.00" to 5.00" Bore Series 3L
Cap Trunnion Mounting XJ + STROKE
Style DB ZB + STROKE
(NFPA Style MT2) Y P + STROKE
UT W LB + STROKE
EE
1
.125R MAX
E 4
SQ. 2 ØTD ØMM
3 F G J K
TL TL
Table 1 – Dimensional and Mounting Data
Bore E EE F G J K TD Ø TL UT Add Stroke
Ø +.000
NPTF 1 SAE 2 -.001 LB P
1.00 3 4 1/4 5 6 0.38 1.50 1.00 0.19 0.750 0.75 3.00 3.88 2.13
1.50 2.00 3/8 5 6 6 0.38 1.50 1.00 0.25 1.000 1.00 4.00 4.00 2.25
2.00 2.50 3/8 5 6 0.38 1.50 1.00 0.31 1.000 1.00 4.50 4.00 2.25
2.50 3.00 3/8 5 6 0.38 1.50 1.00 0.31 1.000 1.00 5.00 4.13 2.38
3.25 3.75 1/2 10 0.63 1.75 1.25 0.38 1.000 1.00 5.75 4.88 2.63
4.00 4.50 1/2 10 0.63 1.75 1.25 0.38 1.000 1.00 6.50 4.88 2.63
5.00 5.50 1/2 10 0.63 1.75 1.25 0.44 1.000 1.00 7.50 5.13 2.88
Table 2 – Dimensional and Mounting Data
Bore Rod MM W Y Add Stroke Bore Rod MM W Y Add Stroke
Ø No. Rod Ø No. Rod
Ø XJ ZB Ø XJ ZB
Max Max
1 (Std.) 0.500 0.63 1.94 4.00 5.00 1 (Std.) 1.375 1.00 2.69 5.25 6.44
1.00
2 0.625 0.63 1.94 4.00 5.00 2 2.500 1.63 3.31 5.88 7.06
1 (Std.) 0.625 0.63 1.94 4.13 5.06 4.00 3 1.750 1.25 2.94 5.50 6.69
1.50
2 1.000 1.00 2.31 4.50 5.44 4 2.000 1.38 3.06 5.63 6.81
1 (Std.) 0.625 0.63 1.94 4.13 5.13 7 1.000 0.75 2.44 5.00 6.19
2.00 2 1.375 1.25 2.56 4.75 5.75 1 (Std.) 1.750 1.25 2.94 5.75 7.06
3 1.000 1.00 2.31 4.50 5.50 2 3.500 1.63 3.31 6.13 7.44
1 (Std.) 1.000 1.00 2.31 4.63 5.63 3 2.000 1.38 3.06 5.88 7.31
2 1.750 1.50 2.81 5.13 6.13 5.00 4 2.500 1.63 3.31 6.13 7.44
2.50
3 1.375 1.25 2.56 4.88 5.88 5 3.000 1.63 3.31 6.13 7.44
7 0.625 0.63 1.94 4.25 5.25 7 1.000 0.75 2.44 5.25 6.56
1 (Std.) 1.000 0.75 2.44 5.00 6.19 8 1.375 1.00 2.69 5.50 6.81
2 2.000 1.38 3.06 5.63 6.81
3.25
3 1.375 1.00 2.69 5.25 6.44
4 1.750 1.25 2.94 5.50 6.69
1 NPTF ports will be furnished as standard unless SAE straight 5 On 1.00", 1.50", 2.00" and 2.50" bore sizes, the head end (only) pipe
thread ports are specified. thread is not full depth on cylinders with No. 2 rods. Minimum of 3
2 SAE straight thread ports are indicated by port number. full threads available.
3 Cushion adjusting needle valve for 1.00" bore projects beyond sides 6 Straight thread ports on the cap end of 1.50" bore require an adapter
of head and cap. fitting. An adapter fitting is also required on the head end of 1.50"
4 1.00" bore 3L heads are rectangular — see 1.00" bore mounting bore with straight thread ports and Code 2 rod. Adapters are
information page. furnished as standard.
22 Parker Hannifin Corporation
Industrial Cylinder Division
www.parker.com/cylinder Des Plaines, Illinois