Page 58 - Gefran - Inverter system and power supply unit (ADV200 Drive family)
P. 58
58 Inverter System & Power Supply Unit
3.7 Output Data
Pn mot Maximum Output frequency f2
(Recommended asyncronous motor rating, fsw = default) output voltage
Sizes U2
ADV200-6 Heavy Duty Light Duty Maximum Minimum IGBT braking unit
ADV200 - 4 • Basic
ADV200-6 • 690V power supply
@690 Vac @575 Vac @690 Vac @575 Vac [V] [Hz] [Hz]
[kW] [Hp] [kW] [Hp]
5750 75 - - - FVCL=300 Hz
FVOL=150 Hz
6900 90 - - - VF=400 Hz
61100 110 - - - FVCL=200 Hz
FVOL=150 Hz
61320 132 - - - VF=300 Hz
FVCL=200 Hz
71600 160 150 200 200 FVOL=150 Hz
VF=500 Hz
72000 200 200 250 250
72500 250 250 315 350 0.95 x Uln FVCL=0 Hz
73150 315 350 355 400 (Uln = AC voltage FVOL=0,5 Hz External optional
(BUy...-6 series)
73550 355 400 400 450 input) VF=1 Hz
400 kW 400 450 500 500
500 kW 500 550 630 700 FVCL=200 Hz
FVOL=150 Hz
630 kW 630 700 710 800 VF=200 Hz
710 kW 710 800 800 900
900 kW 900 1000 1000 1100
1 MW 1000 1100 1150 1300
1,35 MW 1350 1500 1500 1600
1,65 MW 1650 1800 1800 2000
FVCL = Flux vector CL (Field Oriented Control with feedback); FVOL=Flux vector OL (Open Loop Field Oriented Control).
Rated output current In Rated output current In
(for Asyncronous motor) (For Synchronous motors)
Sizes (fsw = default) (fsw = default)
ADV200-6 Heavy Duty Light Duty Heavy Duty Light Duty
[A] [A] [A] [A]
5750 92 - 75 -
6900 110 - 90 -
61100 133 - 110 -
61320 159 - 130 -
71600 170 210 153 189
72000 210 265 189 238
72500 265 330 238 297
73150 330 375 297 337
73550 375 (1) 415 337 373
400 kW 400 500 360 450
500 kW 500 630 450 567
630 kW 630 710 567 639
710 kW 710 (1) 790 639 711
900 kW 900 1000 810 900
1 MW 1000 (1) 1150 900 (1) 1035
1,35 MW 1300 (1) 1450 1170 (1) 1305
1,65 MW 1600 1770 1440 1593
(1) Current values with an ambient temperature of 35°C.