Page 62 - Gefran - Inverter system and power supply unit (ADV200 Drive family)
P. 62
62 Inverter System & Power Supply Unit
3.9 Order codes
Product identification
ADV - X XXX - X X X - 6 - XX YY -DC - SI
ADV200-6 • 690V power supply
ADV200 - 4 • Basic
EXP-SFTy-ADV safety card SI= included [empty]= not included
DC link power supply versions
Only for parallel versions: XX : YY : Inverter power in kW
04 = 400.0 kW
MS = MASTER 05 = 500.0 kW
SL = SLAVE with 06 = 630.0 kW
MS/SL cable 1m 07 = 710.0 kW
length 09 = 900.0 kW
SL2 = SLAVE with 10 = 1 MW
MS/SL cable 2m 14 = 1.35 MW
length 17 = 1.65 MW
Rated voltage: 6 = 3ph 690 Vac / 6A = 3ph 690 Vac / 60Hz
(factory setting): 50 Hz
Software: X = standard
Braking unit: X = not included B = included
Keypad: X = not included K = included
Potenza inverter in kW:
750 = 75,0 kW 1600 = 160.0 kW
900 = 90,0 kW 2000 = 200.0 kW
1100 = 110,0 kW 2500 = 250.0 kW
1320 = 132,0 kW 3150 = 315.0 kW
3550 = 355.0 kW
Mechanical dimensions of the drive: 5 = size 5
6 = size 6
7 = size 7
Inverter, ADV200 series
Example:
ADV - 5 750 - K X X - 6
Rated voltage: 6 = 690 Vac
(factory setting):
Software: X = standard
Braking unit: X = not included
Keypad: K = included
Inverter power in kW: 750 = 75,0 kW
Mechanical dimensions of the drive: 5= size 5
Inverter, ADV200 series