Page 34 - Parker - Energy Products Division - Multitube (Instrument and Heat Trace Tubing Products)
P. 34

Chemical Processing and Refineries                                               Catalog Number 4200-M-2

                                                                                          Back to Table of Contents




            4041-5300 Temptrace Universal Kit for Self-
            Regulating Bundles

              4041-5300 Temptrace Electric Splice or Tee
              Connection Kit for SL and SH Series
              Self-Regulating Bundles







            Connection Kit Contains:

            (1) 3/4” Pipe Stand          (3) Ring Terminals
            (1) Sealing Grommet          (2) Cable Entry Fittings
            (4) Stainless Steel Pipe Straps    (1) 3/4” Pipe Plug
               (2-large, 2-small)        (1) Grounding Screw
            (1) 3 Hub Box                (2) RTV-103BLK
            (1) Box Cover                (1) SS Label
            (6) Wire Nuts                (2) Reducing Bushings
            (2) Butt Splice Connectors      (3) 1” Heat Shrink Tubes
            (1) SK-612 (Seal Patch Kit)      (3) 3” Heat Shrink Tubes





            Kit can be used to make one input power connection or one input
            power splice connection or one splice/tee connection as well as two
            end termination and RTV for bundle end seal.
            An easily installed combination power splice and tee
            for Self-Regulating Bundle.
            Caution: The heater will come in contact with the power feed wires
            in the junction box. Make sure that the temperature rating of the
            power feed wire insulation is adequate for the heater used.
            Ground Fault Equipment Protection Devices (GFEPDs):
            The IEEE standard (515-1989) for heating cables requires the
            use of GFEPDs with a nominal 30 milliampere trip level for “piping
            systems in classified areas, those areas requiring a high degree
            of maintenance, or which may be exposed to physical abuse or
            corrosive atmospheres.”



























                                                                                       Parker Hannifin Corporation