Page 39 - Parker - Energy Products Division - Multitube (Instrument and Heat Trace Tubing Products)
P. 39
Power Generation
Catalog Number 4200-M-2
Back to Table of Contents
How To Order
IS-Intermittent Steam Purge Bundles
Freeze Protection Bundles Designed For Intermittent (5 minutes) High-Temperature Steam Purge
-
IS B 08 49 B - 5 1 2 C - V 4 B
IS Product B Process Tube Material 08 Process 49 Process B Number 5 Maximum
Family Tube Size Tube Size of Steam Purge
1= Smls Copper Type Process Temperature
IS= DHP O.D. Wall Tubes
Intermittent Alloy No 122. ASTM Thickness 1= 1,000˚F
High B68-B75 See Selection See Selection A= 1 Tube 5= 550˚F (288˚C)
Temperature 2= Welded Stainless Steel Charts Charts B= 2 Tubes 6= 650˚F (343˚C)
Steam Type 316/316L ASTM C= 3 Tubes 7= 750˚F (399˚C)
A269 Imperial Imperial etc. 8= 850˚F (454˚C)
** Intermittent 3= Welded Stainless Steel 9= other
is defined as Type 304 ASTM A269 02=1/8” 16=.016” P= 2 Tube D= 1100˚F (593˚C)
steam purge 03=3/16” 20=.020” Parallel Note: For steam
for 5 minutes B= Smls 316/316L ASTM 04=1/4” 28=.028”
A269 Design purges 400˚F or
or less 05=5/16” 30=.030
C= Smls 304 ASTM A269 06=3/8” 31=.031” less use Parker
D= Smls Monel Type 400 07=7/16” 32=.032” SL or SH Bundle
E= Smls Hastelloy C22 08=1/2” 35=.035” Series. For
H= Smls 316H ASTM A213 10=5/8” temperatures
I = Smls Incoloy 825 40=.040” above 1100˚F
12=3/4” 47=.047”
L= Electropolish Smls 16=1” 49=.049” contact factory.
316/316L ASTM A269
50=.050”
(10Ra Max)
Metric 62=.062”
M= Smls 316/316L
ASTM A213 MA=2mm 65=.065”
83=.083”
S= Silco Smls 316/316L MB=4mm
ASTM A269 MC=6mm Metric
P= PFA Flouropolymer MD=8mm
F= FEP Fluoropolymer ME=10mm 89=.89mm
T= TFE Fluoropolymer MF=12mm 10=1.0mm
7= Parflex 919 PTFE SS MG=14mm 15=1.5mm
Braided Hose MH=16mm 20=2.0mm
9= Customer Specified 25=2.5mm
Tube Material
1 Heating 2 Area C Average V Jacket Material 4 *Maximum B Jacket Color
Cable Classification Environment Jacket Surface
Voltage Ambient V = FR-PVC Temperature N=Black
1= Class I, Condition T = FR-TPE Design B=Blue
1= 120VAC Division 1 Range U = FR-PUR G=Green
2= 240VAC Areas P = PUR 4=140˚F Jacket O=Orange
Low/High R = TPR Y=Yellow
* 240 volt 2= General E = FRPE 140˚F meets NEC P=Purple
cables can Purpose/Class A= -40˚F/80˚F L = LDPE 427.12 for personnel R=Red
be powered I, Division 2 B= -20˚F/95˚F F = PVDF protection W=White
at 208, 240 Areas C= 0˚F/105˚F
or 277 volts D= 10˚F/115˚F Note: Parflex
standard jacket Note: Parflex
material is standard color
FR-PVC jacket is black
Parker Hannifin Corporation