Page 42 - Parker - Energy Products Division - Multitube (Instrument and Heat Trace Tubing Products)
P. 42

Power Generation                                                                 Catalog Number 4200-M-2

                                                                                          Back to Table of Contents

                    CS-Continuous High Temperature Steam Purge Bundles

           Freeze Protection Bundles Designed For Continuous High-Temperature Steam Purge Exposure


                                     -
                              CS B 08 49 B - 5 1 2 C - V 4 B



       CS     Product   B  Process Tube Material  08   Process    49    Process   B   Number    5    Maximum
              Family                                   Tube Size       Tube Size         of         Steam Purge
                           1=  Smls   Copper   Type                                   Process       Temperature
             CS=           DHP                           O.D.             Wall         Tubes
             Continuous       Alloy No 122. ASTM                        Thickness                  1= 1,000˚F
             High             B68-B75                 See Selection    See Selection   A= 1Tube    5= 550˚F (288˚C)
             Temperature   2=  Welded Stainless Steel    Charts          Charts       B= 2Tubes    6= 650˚F (343˚C)
             Steam Purge      Type 316/316L ASTM                                      C= 3 Tubes   7= 750˚F (399˚C)
                              A269                      Imperial         Imperial          etc.    8= 850˚F (454˚C)
                           3=  Welded Stainless Steel                                              9= other
                              Type 304 ASTM A269        02=1/8”         16=.016”      P= 2 Tube    D= 1100˚F
                                                        03=3/16”        20=.020”                   (593˚C)
                           B= Smls 316/316L ASTM        04=1/4”         28=.028”           Parallel
                              A269                      05=5/16”        30=.030            Design  Note: For steam
                           C= Smls 304 ASTM A269        06=3/8”         31=.031”                   purges 400˚F or
                           D= Smls Monei Type 400       07=7/16”        32=.032”                   less use Parker
                           E= Smls Hastelloy C22        08=1/2”         35=.035”                   SL or SH Bundle
                           H= Smls 316H ASTM            10=5/8”                                    Series. For
                           A213                         12=3/4”         40=.040”                   temperatures
                           I =  Smls Incoloy 825        16=1”           47=.047”                   above 1100˚F
                           L=  Electropolish Smls                       49=.049”                   contact factory.
                              316/316L ASTM A269                        50=.050”
                              (10Ra Max)                 Metric         62=.062”
                           M= Smls 316/316L ASTM        MA=2mm          65=.065”
                              A213                      MB=4mm          83=.083”
                           S= Silco Smls 316/316L
                              ASTM A269                 MC=6mm           Metric
                           P= PFA Flouropolymer         MD=8mm          89=.89mm
                           F=  FEP Fluoropolymer        ME=10mm         10=1.0mm
                           T=  TFE Fluoropolymer        MF=12mm
                                                        MG=14mm         15=1.5mm
                           7=  Parflex 919 PTFE SS      MH=16mm         20=2.0mm
                              Braided Hose                              25=2.5mm
                           9=  Customer Specified
                              Tube Material






         1   Heating    2      Area      C     Average     V  Jacket Material  4   Jacket Surface   B  Jacket Color
              Cable        Classification    Environment                          Temperature
             Voltage                           Ambient          V=FR-PVC             Design           N=Black
                           1= Class I,        Condition         T=FR-TPE                              B=Blue
            1= 120VAC      Division 1 Areas     Range           U=FR-PUR          4=140˚F Jacket      G=Green
            2= 240VAC                                           P=PUR             6=160˚F Jacket      O=Orange
                           2= General          Low/High         R=TPR             8= 180˚F Jacket     Y=Yellow
            * 240 volt     Purpose/Class I,                     E=FRPE                                P=Purple
            cables can     Division 2 Areas  A= -40˚F/80˚F      L=LDPE           * Jacket surface     R=Red
            be powered                       B= -20˚F/95˚F      F=PVDF           temperature will     W=White
            at 208, 240                      C=   0˚F/105˚F   Note: Parflex      not exceed this
            or 277 volts                     D= 10˚F/115˚F                       maximum when
                                                              standard jacket                       Note: Parflex
                                                                                 the bundle is
                                                              material is        operated at        standard color
                                                              FR-PVC                                jacket is black
                                                                                 the designed
                                                                                 steam purge
                                                                                 temperature at the
                                                                                 highest ambient
                                                                                 design condition


                                                                                       Parker Hannifin Corporation
                                                             39                        Energy Products Division                                                                         40
   37   38   39   40   41   42   43   44   45   46   47