Page 42 - Parker - Energy Products Division - Multitube (Instrument and Heat Trace Tubing Products)
P. 42
Power Generation Catalog Number 4200-M-2
Back to Table of Contents
CS-Continuous High Temperature Steam Purge Bundles
Freeze Protection Bundles Designed For Continuous High-Temperature Steam Purge Exposure
-
CS B 08 49 B - 5 1 2 C - V 4 B
CS Product B Process Tube Material 08 Process 49 Process B Number 5 Maximum
Family Tube Size Tube Size of Steam Purge
1= Smls Copper Type Process Temperature
CS= DHP O.D. Wall Tubes
Continuous Alloy No 122. ASTM Thickness 1= 1,000˚F
High B68-B75 See Selection See Selection A= 1Tube 5= 550˚F (288˚C)
Temperature 2= Welded Stainless Steel Charts Charts B= 2Tubes 6= 650˚F (343˚C)
Steam Purge Type 316/316L ASTM C= 3 Tubes 7= 750˚F (399˚C)
A269 Imperial Imperial etc. 8= 850˚F (454˚C)
3= Welded Stainless Steel 9= other
Type 304 ASTM A269 02=1/8” 16=.016” P= 2 Tube D= 1100˚F
03=3/16” 20=.020” (593˚C)
B= Smls 316/316L ASTM 04=1/4” 28=.028” Parallel
A269 05=5/16” 30=.030 Design Note: For steam
C= Smls 304 ASTM A269 06=3/8” 31=.031” purges 400˚F or
D= Smls Monei Type 400 07=7/16” 32=.032” less use Parker
E= Smls Hastelloy C22 08=1/2” 35=.035” SL or SH Bundle
H= Smls 316H ASTM 10=5/8” Series. For
A213 12=3/4” 40=.040” temperatures
I = Smls Incoloy 825 16=1” 47=.047” above 1100˚F
L= Electropolish Smls 49=.049” contact factory.
316/316L ASTM A269 50=.050”
(10Ra Max) Metric 62=.062”
M= Smls 316/316L ASTM MA=2mm 65=.065”
A213 MB=4mm 83=.083”
S= Silco Smls 316/316L
ASTM A269 MC=6mm Metric
P= PFA Flouropolymer MD=8mm 89=.89mm
F= FEP Fluoropolymer ME=10mm 10=1.0mm
T= TFE Fluoropolymer MF=12mm
MG=14mm 15=1.5mm
7= Parflex 919 PTFE SS MH=16mm 20=2.0mm
Braided Hose 25=2.5mm
9= Customer Specified
Tube Material
1 Heating 2 Area C Average V Jacket Material 4 Jacket Surface B Jacket Color
Cable Classification Environment Temperature
Voltage Ambient V=FR-PVC Design N=Black
1= Class I, Condition T=FR-TPE B=Blue
1= 120VAC Division 1 Areas Range U=FR-PUR 4=140˚F Jacket G=Green
2= 240VAC P=PUR 6=160˚F Jacket O=Orange
2= General Low/High R=TPR 8= 180˚F Jacket Y=Yellow
* 240 volt Purpose/Class I, E=FRPE P=Purple
cables can Division 2 Areas A= -40˚F/80˚F L=LDPE * Jacket surface R=Red
be powered B= -20˚F/95˚F F=PVDF temperature will W=White
at 208, 240 C= 0˚F/105˚F Note: Parflex not exceed this
or 277 volts D= 10˚F/115˚F maximum when
standard jacket Note: Parflex
the bundle is
material is operated at standard color
FR-PVC jacket is black
the designed
steam purge
temperature at the
highest ambient
design condition
Parker Hannifin Corporation
39 Energy Products Division 40