Page 45 - Parker - Energy Products Division - Multitube (Instrument and Heat Trace Tubing Products)
P. 45

Process Control & Analyzer Systems
            Catalog Number 4200-M-2
               Back to Table of Contents




 CL— Constant Wattage Electric Trace Tubing —
 Low Temperature Maintenance   Electrical Specifications:

                  Heater type            4 W./ft.              11.4W./ft.
                                                                  ®
                   Insulation      PFA Teflon® 600 V rated  PFA Teflon 600V rated
                  Bus wire size          12 AWG                 12 AWG
              Heating zone length**          18" (45.7 cm) and 24" (61 cm)






                Part     Power Consumption   Voltage   Maximum Circuit   Current A/ft (A/m)
              Number         W/ft (W/m)                 Length*** ft (m)
               Series


                 CL             4             120           340               0.033
                                                           (103.6)           (0.108)
                               (13.1)
                                              240           680               0.017
                                                           (207.3)            (0.55)
                 CL            11.4           120           200               0.095
                                                            (61)             (0.312)
                               (37.4)
                                              240           400              0.0485
                                                            (122)            (0.156)

            ***Based on 10% power drop.
            For recommended temperature controller, see 4012-01145
            (G.P. areas) and 4012-01147 (Hazardous locations).


                                                            Ground Fault Equipment Protection Devices (GFEPDs):
                 Approvals:
                                                            The IEEE standard (515-1989) for heating cables requires
                 Ordinary Locations                         the use of GFEPDs with a nominal 30 milliampere trip
                                                            level for “piping systems in classified areas, those areas
                 FM – Factory Mutual Approved
                                                            requiring a high degree of maintenance, or which may be
                 Hazardous (Classified) Locations
                                                            exposed to physical abuse or corrosive atmospheres.”
                 FM – Factory Mutual Approved

                 Class I, Division 2, Groups B, C and D
                 Class II, Division 2, Groups F and G
                                                            For performance characteristics see next
                 Class III, Division 1 and 2
                                                            page.

            **Installation Note:
               Caution: Cutting beyond heating zone
              indentation will result in an unheated
              section of the heater wire for the balance
              of the heating zone length. The bus wires
              MUST NOT be connected together on the
              termination end!