Electrical Specifications:
Heater type 12 W./ft. 18 W./ft.
Insulation Kapton ® Kapton ®
Bus wire size 12 AWG 12 AWG
Heating Average 48” (121.9 cm) for high temperature
zone length** Kapton® insulated heater wires
Part Power Voltage Maximum Circuit Current A/ft (A/m)
Number Consumption Length*** ft (m)
Series W/ft (W/m)
180 0.100
12 120 (54.9) (0.3281)
CH
(39.3) 240 360 0.050
(109.7) (0.164)
147 0.150
18.0 120 (44.8) (0.49)
CH
(58.95) 240 294 0.075
(89.6) (0.246)
***Based on 10% power drop.
For recommended temperature controller, see 4012-01145 (G.P. areas) and
4012-01147 (Hazardous locations) in Section F.
Ground Fault Equipment Protection Devices (GFEPDs):
Approvals: The IEEE standard (515-1989) for heating cables requires
Ordinary Locations the use of GFEPDs with a nominal 30 milliampere trip level
FM – Factory Mutual Approved for “piping systems in classified areas, those areas requiring
a high degree of maintenance, or which may be exposed to
Hazardous (Classified) Locations
physical abuse or corrosive atmospheres.”
FM – Factory Mutual Approved
Class I, Division 2, Groups B, C and D
Class II, Division 2, Groups F and G
Class III, Division 1 and 2
**Installation Note:
Caution: Cutting beyond heating zone indentation will result
in an unheated section of the heater wire for the balance of the
heating zone length. The bus wires MUST NOT be connected
together on the termination end!