Page 51 - Parker - Energy Products Division - Multitube (Instrument and Heat Trace Tubing Products)
P. 51
Process Control & Analyzer Systems
Catalog Number 4200-M-2
Back to Table of Contents
Performance Data—Single Process Tube
CH Constant Watt Low Temperature Heater 8 watt/ft - Single Tube Designs
250 121
Stabilized Process Temperature (°F) 150 1/4" 3/8" 1/2" 66 Stabilized Process Temperature (°C)
200
73
100
38
50
45
7
°F -60 -40 -20 0 20 32 40 60 80 100 10
-50 -40 -30 -20 -10 0 10 20 30 40 °C
Ambient Temperature
Performance Data—Dual Process Tube
CH Constant Watt High Temperature Heater 8 watt/ft - Dual Tube Designs
250 121
Stabilized Process Temperature (°F) 150 (2) 1/4" (2) 1/2" 66 Stabilized Process Temperature (°C)
200
73
100
38
(2) 3/8"
50
45
7
°F -60 -40 -20 0 20 32 40 60 80 100 10
-50 -40 -30 -20 -10 0 10 20 30 40 °C
Ambient Temperature
Parker Hannifin Corporation
47 48 Energy Products Division