Page 46 - Parker - Energy Products Division - Multitube (Instrument and Heat Trace Tubing Products)
P. 46
Process Control & Analyzer Systems Catalog Number 4200-M-2
Back to Table of Contents
Performance Data—Single Process Tube
CL Constant Watt Low Temperature Heater 4 watt/ft - Single Tube Designs
250 121
Stabilized Process Temperature (°F) 150 1/4" 3/8" 66 Stabilized Process Temperature (°C)
200
73
38
100
50
1/2"
45
7
°F -60 -40 -20 0 20 32 40 60 80 100 10
-50 -40 -30 -20 -10 0 10 20 30 40 °C
Ambient Temperature
Performance Data—Dual Process Tube
CL Constant Watt Low Temperature Heater 4 watt/ft - Dual Tube Designs
250 121
Stabilized Process Temperature (°F) 150 (2)3/8" 66 Stabilized Process Temperature (°C)
200
73
38
100
(2)1/4"
50
(2)1/2"
45
7
°F -60 -40 -20 0 20 32 40 60 80 100 10
-50 -40 -30 -20 -10 0 10 20 30 40 °C
Ambient Temperature
Parker Hannifin Corporation
43 Energy Products Division 44