Page 48 - Parker - Energy Products Division - Multitube (Instrument and Heat Trace Tubing Products)
P. 48
Process Control & Analyzer Systems Catalog Number 4200-M-2
Back to Table of Contents
CL Series Constant Watt Bundles
Maximum Exposure 400°F (204°C)
Process Tubes 1/4” to 1/2” O.D. (6mm to 12mm)
Single or Dual Tube Designs
Standard Insulation Package *
Minimum
Environments Average High / Low Ambient Conditions
Process
Temperature Extreme Cold Cold Moderate Cold Moderate Warm
to Maintain -65°F Low -40°F Low -10°F Low 0°F Low 10°F Low
80°F High 80°F High 95°F High 105°F High 115°F High
-54°C Low -40°C Low -24°C Low -18°C Low -13°C Low
120 Volts
26°C High 26°C High 35°C High 40°C High 46°C High
40°F (4˚C) 8 Watt / Ft 8 Watt / Ft 4 Watt / Ft 4 Watt / Ft 4 Watt / Ft
50°F (10˚C) 11.4 Watt / Ft 8 Watt / Ft 8 Watt / Ft 4 Watt / Ft 4 Watt / Ft
75°F (24˚C) 11.4 Watt / Ft 11.4 Watt / Ft 8 Watt / Ft 8 Watt / Ft 8 Watt / Ft
100°F (38˚C) 18 Watt / Ft 11.4 Watt / Ft 11.4 Watt / Ft 8 Watt / Ft 8 Watt / Ft
125°F (52˚C) 18 Watt / Ft 18 Watt / Ft 11.4 Watt / Ft 11.4 Watt / Ft 11.4 Watt / Ft
150°F (66˚C) 18 Watt / Ft 18 Watt / Ft 18 Watt / Ft 18 Watt / Ft 11.4 Watt / Ft
175°F (79˚C) 18 Watt / Ft 18 Watt / Ft 18 Watt / Ft 18 Watt / Ft
200°F (93˚C) 18 Watt / Ft 18 Watt / Ft 18 Watt / Ft
225°F (107˚C) 18 Watt / Ft 18 Watt / Ft 18 Watt / Ft
208 Volts
40°F (4˚C) 8 Watt / Ft 8 Watt / Ft 8 Watt / Ft 4 Watt / Ft 4 Watt / Ft
50°F (10˚C) 11.4 Watt / Ft 8 Watt / Ft 8 Watt / Ft 4 Watt / Ft 4 Watt / Ft
75°F (24˚C) 11.4 Watt / Ft 11.4 Watt / Ft 15 Watt / Ft 8 Watt / Ft 8 Watt / Ft
100°F (38˚C) 18 Watt / Ft 11.4 Watt / Ft 15 Watt / Ft 8 Watt / Ft 8 Watt / Ft
125°F (52˚C) 18 Watt / Ft 20 Watt / Ft 11.4 Watt / Ft 11.4 Watt / Ft
150°F (66˚C) 18 Watt / Ft 11.4 Watt / Ft 11.4 Watt / Ft
175°F (79˚C) 18 Watt / Ft 18 Watt / Ft
240 Volts
40°F (4˚C) 8 Watt / Ft 8 Watt / Ft 4 Watt / Ft 4 Watt / Ft 4 Watt / Ft
50°F (10˚C) 11.4 Watt / Ft 8 Watt / Ft 8 Watt / Ft 4 Watt / Ft 4 Watt / Ft
75°F (24˚C) 11.4 Watt / Ft 11.4 Watt / Ft 8 Watt / Ft 8 Watt / Ft 8 Watt / Ft
100°F (38˚C) 18 Watt / Ft 11.4 Watt / Ft 11.4 Watt / Ft 8 Watt / Ft 8 Watt / Ft
125°F (52˚C) 18 Watt / Ft 18 Watt / Ft 11.4 Watt / Ft 11.4 Watt / Ft 11.4 Watt / Ft
150°F (66˚C) 18 Watt / Ft 18 Watt / Ft 18 Watt / Ft 18 Watt / Ft 11.4 Watt / Ft
175°F (79˚C) 18 Watt / Ft 18 Watt / Ft 18 Watt / Ft 18 Watt / Ft
200°F (93˚C) 18 Watt / Ft 18 Watt / Ft 18 Watt / Ft
225°F (107˚C) 18 Watt / Ft 18 Watt / Ft 18 Watt / Ft
* The above heater cable selection is based upon our standard insulation package, other insulation packages are available to maintain higher
temperatures.
How to Use: Note:
The watt-density selected
1) Check to be sure you are using the correct chart.
will maintain the temperature
2) Choose your operating voltage.
indicated at a minimum.
3) Choose the minimum process temperature you want to maintain. Depending upon actual ambient
Note: If temperature is not shown, pick the next higher option. fluctuations, process tubes
size and number of tubes, the
4) Follow chart across to the ambient Condition that best match your area.
maintenance temperature could
5) Use the watt-density shown for your part number derivation.
be higher.