Page 48 - Linde - VT1 Modular, modular system for LSC manifold valve plates
P. 48
4 | System components. replacement parts
Solenoid MSP24 und MSP12 with Deutsch connector
By means of a replacement, pilot controls DMV1 and DMV2
can each be converted from 24V to 12V or vice versa.
MSP24 MSP12
>> MSP24
>> MSP12
Throttle check valves DRV
The directional control valves may be equipped with throttle check valves DRV to influence the stroking speed of the control
spool. They are screwed into the pilot pressure ports of the control caps with a tightening torque of 9 Nm.
DRV
>> DRV1.0
>> DRV1.15
Hydraulische Durchsteuerzeiten durch Drosselrückschlagventile (DRV)
>> DRV1.35
Pilot range Time Tolerances t [ms]/ t [ms]/
open closed
[ms] DRV DRV
Medium 290/ 380/
(300-400 ms) ±30 DRV1.15 DRV1.15
6–19 bar For Directional control valves VW25-CF25
Slow 350/ 460/
(400-700 ms) ±40 DRV1.0 DRV1.0
Pilot range Time Tolerances t [ms]/ t [ms]/
open closed
[ms] DRV DRV
Medium ±30 290/ 440/
(300-400 ms) DRV1.35 DRV1.35
6–19 bar For Directional control valves VW30-CF25
Slow 430/ 650/
(400-700 ms) ±40 DRV1.15 DRV1.15
Hydraulic advanced control times measured at 60 °C - 27 cStv
48