Page 48 - Linde - VT1 Modular, modular system for LSC manifold valve plates
P. 48

4 | System components. replacement parts


            Solenoid MSP24 und MSP12 with Deutsch connector
            By means of a replacement, pilot controls DMV1 and DMV2
            can each be converted from 24V to 12V or vice versa.
                                                    MSP24       MSP12













             >> MSP24
             >> MSP12
            Throttle check valves DRV
            The directional control valves may be equipped with throttle check valves DRV to influence the stroking speed of the control
            spool. They are screwed into the pilot pressure ports of the control caps with a tightening torque of 9 Nm.


                                                           DRV












             >> DRV1.0
             >> DRV1.15
            Hydraulische Durchsteuerzeiten durch Drosselrückschlagventile (DRV)
             >> DRV1.35

             Pilot range  Time        Tolerances   t   [ms]/  t   [ms]/
                                                 open       closed
                                        [ms]       DRV        DRV
                         Medium                    290/       380/
                         (300-400 ms)   ±30      DRV1.15    DRV1.15
               6–19 bar                                                For Directional control valves  VW25-CF25
                         Slow                      350/       460/
                         (400-700 ms)   ±40       DRV1.0     DRV1.0



             Pilot range  Time        Tolerances   t  [ms]/  t  [ms]/
                                                 open       closed
                                        [ms]       DRV        DRV
                         Medium         ±30        290/       440/
                         (300-400 ms)            DRV1.35    DRV1.35
               6–19 bar                                                For Directional control valves  VW30-CF25
                         Slow                      430/       650/
                         (400-700 ms)   ±40       DRV1.15   DRV1.15










            Hydraulic advanced control times measured at 60 °C - 27 cStv


      48
   43   44   45   46   47   48   49   50   51   52   53