Page 53 - Linde - VT1 Modular, modular system for LSC manifold valve plates
P. 53
5 | Assembly of System components. VT1EE with KT3, KT5 check modules
VT1EE with or without tank check
VT1EE with tank check at T2
At tank port T2 of the VT1EE, a KT3 or KT5 tank check module can be mounted in three different
directions. Tank port T1 must be sealed with an SAE 1 1/2” closing flange.
KT3 or KT5 closing flange
T2 T1
Three possible
connection directions
each offset by 90°
circuit diagram
Port Port size DN Max. per-
function missible
pressure
T2 - Tank SAE 1 1/2’’ ISO 6162-1 38 10bar
4x M12 / 21.5 deep / M =
A
130Nm 1)
1) dependent on screwproperty class according to ISO
SAE closing flange 1 1/2’’
(with O-Ring-47,22x3,55-V80)
T2 T1
4x ZS-M8x110-912-8.8 4x ZS-M12x45-912-8.8
Mounting bolts, Tightening Mounting bolts, Tightening
torque 23Nm torque 86Nm
During assembly or installation, proper handling of the O-rings must be ensured.
53