Page 50 - Linde - VT1 Modular, modular system for LSC manifold valve plates
P. 50

5 | Assembly of System components. VT1EE with KT3, KT5 check modules


            VT1EE with or without tank check
            T1EE without tank check
            On the VT1EE, there are two tank ports T1 and T2, each designed as SAE 1 1/2”, ISO 6162-1. If no additional
            tank check function is desired, a simple tank port can be provided there.
























                                                         You can also choose to seal the unused tank port T1 or T2 with an
                                                         SAE 1 1/2” closing flange
                                                         (with O-ring 47.22x3.55-V80 and 4x ZS-M12x45-912-8.8,
                                                         tightening torque 86 Nm)


            circuit diagram
                                                              Port             Port size        DN  Max. per-
                                                            function                                 missible
                                                                                                     pressure
                                                             T1, T2 -     SAE 1 1/2’’ ISO 6162-1  38  10bar
                                                              Tank      4x M12 / 21.5 deep / M =
                                                                                          A
                                                                              130Nm  1)
                                                          1) dependent on screwproperty class according to ISO






























                                        During assembly or installation, proper handling of the O-rings must be ensured.