Page 51 - Linde - VT1 Modular, modular system for LSC manifold valve plates
P. 51

5 | Assembly of System components. VT1EE with KT3, KT5 check modules


            VT1EE with or without tank check
            VT1EE with tank check
            For a tank check function at tank ports T1 and T2, the desired KT3 and KT5 modules must be attached in each case. There are
            three possible connection directions.











                                  T2                                                  T1
            Three possible                                                                  Three possible
            connection directions                                                           connection direc-
            each offset by 90°                                                              tions
                                                                                            each offset by 90°




                                                   KT3, KT5 selective at T1, T2








            circuit diagram
                                                              Port             Port size        DN  Max. per-
                                                            function                                 missible
                                                                                                     pressure
                                                             T1, T2 -     SAE 1 1/2’’ ISO 6162-1  38  10bar
                                                              Tank      4x M12 / 21.5 deep / M =
                                                                                          A
                                                                              130Nm  1)
                                                          1) dependent on screwproperty class according to ISO









               8x ZS-M8x110-912-8.8
               Mounting bolts, Tightening torque 23Nm







                  T1                                                                                T2








                                        During assembly or installation, proper handling of the O-rings must be ensured.






                                                                                                                 51
   46   47   48   49   50   51   52   53   54   55   56