Page 20 - TRD
P. 20

Year            Monkey           Bird             Bad         Tree/coal  Sidings        Total
                            Electrocuted  Electrocuted  Weather  fallen                 CB

            2021-22
                        st
            (  As  on  31        167               35             83           23          150        684
            Oct)

            Analysis of CB tripping:

                             CB Tripping
                                                                              Monkey Electrocuted



                                                                              Bird Electrocuted



                                           25%                                Bad Weather
                        33%

                                                                              With Siding CB/BM
                                               5%

                         3%                 12%                               Tree/Coal Fallen on Loco Roof

                                22%
                                                                              Others



          The following preventive measures taken to reduce CB trippings:

             Sl.No.  Preventive Measures           Action Taken
             1.       Replacement             of  1030        No’s      Stay
                      Bracket/Stay  insulators  insulators,
                      with     composite       in  856No.s          bracket
                      stone pelting areas.         insulators changed


             2.       Nylon  mesh  provision  37 Nos. Of Portals.
                      in  portals  to  reduce
                      the bird nest forming.





             3.       Tree  trimming  in  the  89107 Tree trimming
                      mainline and siding.
   15   16   17   18   19   20   21