FIG: Replacement of jumpers

             Replacement of worn-out contact wire:

              In  BPA  jurisdiction  between  the  locations  241/22-242/25,  the  960  mts  of  worn-out
              contact wire (one TL) has been replaced, due to dia of the contact wire reduced
              to 8.25 mm.  As per railway board norm it should be more than 8.25 mm.













                                                          Fig: Replacement of  contact wire


             Provision of long creeping composite insulators:
              Long  creep  age  composite  insulators  were  provided  in  stone  pelting  areas  in
              bonakallu (BKL) section and polluted areas in Sanath Nagar section in the division to
              avoid  the  breakage  of  insulators  and  CB  trippings.  31  no’s  Long  creepage
              composite insulators are replaced during this month at BKL jurisdiction.








                                    Fig: Repalcement Of Composite insulators
             Provision of Sigma Boards ahead of STOP Signals:

              To  assist  Loco  pilots  for  easily  identifying  the
              STOP  signals  during  foggy  weather  conditions,
              Division  has  taken  up  the  work  of  provision  of
              Retro  reflective  SIGMA  boards,  ahead  of  the
              STOP signals.