Page 14 - TRD
P. 14
Fig: Replacement of NICCO contact wire
Provision of Anti monkey climbing devises:
The reason for around 21% CB Trippings in the divison are due to electricution of
monkeys. The monkey menance are lofty in DKJ, Aler and NKD sections in the
Division. To decress the monkey menance, division has taking many streps and anti
monkey climbing devices are one among those. 1126 Anti monkey climbing
devices are provided.
Fig: AMCD provided at DKJ junction.
Muff raising:
Muff is an additional concreting done on top of foundation to prevent
accumulation of water around the mast and thus prevents corrosion of mast at the
foundation level. Due to aging and other factors the Muff in many locations are
destroyed. Muffing was provided for 486 locations in ALER section.
Fig: Muffing work@ Aler
Replacement of Rusted ACC:
In polluted areas like SNF and KI, TDU, the anti-creep wires became rusted, due to
this the mechanical strength of the wire was decreased. The snapping of which
may leads to major breakdown. To avert this Division has come up with