Page 15 - TRD
P. 15

replacement  of  rusted  Anti  Creep  wires.  Total  33  rusted  Anti  creep  wires  are

              replaced.









                                        Fig: Replacement of rusted ACC
            Replacement of Rusted cantilevers:

              Rusted cantilevers are the one of the causes for breakdowns in polluted areas. Due
              to the rusting of the rusting of the cantilever tubes, the mechanical strength of the

              cantilever will decreases drastically and leads to breakdown of OHE. To avert the
              failures due to rusting of cantilevers, replacement work has taken up and replaced
              911 No’s in pollution prone areas.










                                            Fig: Rusted cantilever and replacement.

             Adjustment of contact wire height @ RD-6 in SC yard:

              To facilitate the provision for running of over dimentioned consignment (ODC), the
              contact  wire  height  at  road-6  in  SC  was  incresed  from  5  mts  to  5.46  mts.  as  the
              existing- less height  FOB was dismatled by engineering department.













                                           Fig: Height adjustment work.

             Replacement of Isolators and Jumpers:

              As per the Railway Board and Headquarters guide lines, all the 800 Amps Isolators

              and Isolator jumpers in the Main line should replaced with 1250 Amps and 160 Sq.
              mm Jumpers respectively for increasing the section speed between BPQ-KI to 160
              KMPH.