Steel
CATEGORIZATION OF DEFECTS
Other type of flaws and “Safe Side” categorization
INCLUDES:
▪ Other type of faults and damages on steel elements and structures not
categorized previously in this document.
CATEGORIZATION / ACTION:
▪ Categorization shall be based on the “best judgment” and consider how critical is
the steel element for the entire structure and what could the timeline for a further
degradation leading to a failure of the element.
▪ In case of doubt, it is recommended that the inspector categorize the LFF in a
conservative way (higher LFF) and trigger immediate reparation or Expert
Assessment, if applicable.
▪ Criticality of a member or a part of a member shall be considered. Critical
members are those essential for the structural integrity (e.g. columns, welds in
suspended hopper).
▪ Consider the possibility of some members apparently not loaded during an
inspection may be occasionally extremely loaded (example: Effect of lateral wind
load on bracing elements).
Examples:
Misalignment of members Missing members Internal welding
Partly bolted
and partly welded Cuts on plates to fit bolts Fire damage